ABLESTIK FDA 2
Harmonization Code : 3506.91.90.99 | Prepared glues and other prepared adhesives, not elsewhere specified or included; products suitable for use as glues or adhesives, put up for retail sale as glues or adhesives, not exceeding a net weight of 1 kg ; Adhesives based on polymers of headings 3901 to 3913 or on rubber; Other ; Other

Main features
- 1.20 x 10^14 ohm-cm Volume Resistivity
- 3-Hour Working Window
- 1,800 psi Aluminum Lap Shear
Product Description
LOCTITE® ABLESTIK FDA 2 BIPAX is a two-part, electrically insulating epoxy adhesive for medical-device bonding applications. Formerly known as TRA-BOND FDA2, the amber, medium-viscosity system mixes at 100:100 by weight and provides a typical pot life of 45 minutes and work life of 3 hours. It can be cured for 24 hours at 25°C or accelerated for 1 to 4 hours at 65°C. The cured adhesive has a documented operating-temperature range of -70 to 145°C, typical volume resistivity of 1.20 × 1014 ohm-cm at 25°C, and aluminum-to-aluminum lap shear strength of 1,800 psi.
Key features
- Electrically insulating: Typical cured properties include volume resistivity of 1.20 × 1014 ohm-cm at 25°C and dielectric strength of 420 V/mil.
- Medium-viscosity processing: Typical mixed viscosity of 14,000 mPa·s at 25°C supports controlled adhesive application.
- Room-temperature or heat cure: Guideline schedules include 24 hours at 25°C or 1 to 4 hours at 65°C.
Applications / Suitable for
- Catheters
- Hearing aids
- Dental products
- Other biomedical instruments and devices
TDS, SDS & Technical Documents
Technical Specifications
General Properties
Thermal Properties
Physical Properties
Mechanical Properties
Electrical Properties
Additional Information
As-supplied / before-processing properties
Typical properties and processing characteristics of the mixed two-part adhesive before cure.
| Property | Value | Unit | Method / condition |
|---|---|---|---|
| Technology | Epoxy | — | Two-part resin and hardener system |
| Color | Amber | — | Mixed adhesive |
| Mix ratio — resin:hardener | 100:100 | by weight | Resin-to-hardener ratio |
| Mixed viscosity | 14,000 | mPa·s (cP) | Brookfield RV, spindle 7, 10 rpm at 25°C |
| Thixotropic index | 1.0 | — | Test details not stated |
| Specific gravity — mixed | 1.12 | — | Mixed adhesive |
| Reactive solids content | 100 | % | Typical value |
| Pot life | 45 | minutes | Test conditions and endpoint not stated |
| Work life | 3 | hours | Test conditions and endpoint not stated |
| Cure schedule | 24 hours or 1–4 hours | — | 24 hours at 25°C or 1–4 hours at 65°C; guideline recommendations |
| Optimal storage | 27 | °C | Store unopened in a dry location; package labeling governs applicable storage information |
After-processing / final-state properties
Typical properties and performance data for the cured adhesive. Values are reference data and are not product specifications.
| Property | Value | Unit | Method / condition |
|---|---|---|---|
| Operating-temperature range | -70 to 145 | °C | Documented product range |
| Coefficient of thermal expansion | 5.30 × 10-5 | cm/cm/°C | Method, temperature region, and cure condition not stated |
| Glass-transition temperature | 54 | °C | Ultimate Tg; method and cure condition not stated |
| Hardness | 80 | Shore D | Method and cure condition not stated |
| Elongation | 9 | % | Method and cure condition not stated |
| Volume resistivity at 25°C | 1.20 × 1014 | ohm-cm | Test method and specimen configuration not stated |
| Dielectric strength | 420 | V/mil | Test method, thickness, and conditioning not stated |
| Dielectric constant | 3.4 | — | At 25°C and 1 kHz |
| Dissipation factor | 0.02 | — | At 25°C and 1 kHz |
| Lap shear strength — aluminum to aluminum | 1,800 | psi | Substrate preparation, bondline, cure condition, test method, and test temperature not stated |